-
Burette, class AS, PTFE stopcock, pc
• Burette, glass, class AS, PTFE stopcock
• 1 piece
VOLUMES AVAILABLE:
• 3295/12AS: 10ml x 0.02ml
• 3295/14AS: 25ml x 0.10ml
• 3295/16AS: 50ml x 0.10ml
• 3295/18AS: 100ml x 0.20ml -
Volumetric Flask, class A, ISO/DIN/USP, PE stopper, batch cert, pc
• Volumetric Flask, glass, class A, ISO/DIN/USP, PE stopper, batch cert.
• 1 piece
VOLUMES AVAILABLE:
• 3151/04: 5ml
• 3151/06: 10ml
• 3151/08: 20ml
• 3151/10: 25ml
• 3151/12: 50ml
• 3151/14: 100ml
• 3151/16: 200ml
• 3151/18: 250ml
• 3151/20: 500ml
• 3151/22: 1L
• 3151/24: 2L -
Filter Funnel, plain, 60°, short stem, pc
• Filter Funnel, glass, plain, 60°, short stem
• 1 piece
DIAMETERS AVAILABLE:
• 2140/02M, 45mm dia
• 2140/03M, 70mm dia
• 2140/06M, 80mm dia
• 2140/10M, 105mm dia
• 2140/11M, 125mm dia
• 2140/12M, 150mm dia -
8-channel Pipette
*Buy 1 Free 1 Promotion, while stock lasts
A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.
VOLUMES AVAILABLE:
•SPIP-B10: Volume Range: 1-10 μL, Increment: 0.1 μL
•SPIP-B300: Volume Range: 50-300 μL, Increment: 1 μL
•SPIP-B1000: Volume Range: 100-1000 μL, Increment: 5 μL -
Single-channel Pipette
*Buy 1 Free 1 Promotion, while stock lasts
A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.
VOLUMES AVAILABLE:
•SPIP-2.5: Volume Range: 0.1-2.5 μL, Increment: 0.05 μL
•SPIP-10: Volume Range: 1-10 μL, Increment: 0.1 μL
•SPIP-20: Volume Range: 2-20 μL, Increment: 0.1 μL
•SPIP-100: Volume Range: 10-100 μL, Increment: 1 μL
•SPIP-200: Volume Range: 20-200 μL, Increment: 1 μL
•SPIP-1000: Volume Range: 100-1000 μL, Increment: 5 μL
•SPIP-5000: Volume Range: 1000-5000 μL, Increment: 50 μL
•SPIP-10000: Volume Range: 1-10 mL, Increment: 100 μL -
Memmert ICH260C Climate Chamber [Resale]
*Additional charge for installation
*One Science does not handle the warranty for resale items
Setting temperature range: -10 to +60 °C
Working temperature range: from -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over)
Working temperature range: from +10°C up to +60°C with humidity and/or light
Setting accuracy temperature: 0.1 °C
Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Works calibration certificate: standard values +10 °C and +37 °C, 60 % rh at +30 °C
Door: inner glass doors
Door: fully insulated stainless steel doors with 2-point locking (compression door lock)
Entry port: Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back
Humidity: humidity supply with distilled water from external tank by self-priming pump
Humidification: humidification by hot steam generator
Humidity: active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity – resolution of display 0.1 %, setting accuracy 0.5 %
Fan: forced air circulation
External Dimensions: w(D) x h(E) x d(F): 824 x 1552 x 685 mm (d +56mm door handle)
Internal Dimensions: w(A) x h(B) x d(C): 640 x 800 x 500 mm (d less 33 mm for fan)
Volume: 256 l
Max. number of internals: 9
Max. loading of chamber: 200 kg
Max. loading per internal: 20 kg