• 8-channel Pipette

    *Buy 1 Free 1 Promotion, while stock lasts


    A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.


    VOLUMES AVAILABLE:
    •SPIP-B10: Volume Range: 1-10 μL, Increment: 0.1 μL
    •SPIP-B300: Volume Range: 50-300 μL, Increment: 1 μL
    •SPIP-B1000: Volume Range: 100-1000 μL, Increment: 5 μL

  • Single-channel Pipette

    *Buy 1 Free 1 Promotion, while stock lasts


    A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.


    VOLUMES AVAILABLE:
    •SPIP-2.5: Volume Range: 0.1-2.5 μL, Increment: 0.05 μL
    •SPIP-10: Volume Range: 1-10 μL, Increment: 0.1 μL
    •SPIP-20: Volume Range: 2-20 μL, Increment: 0.1 μL
    •SPIP-100: Volume Range: 10-100 μL, Increment: 1 μL
    •SPIP-200: Volume Range: 20-200 μL, Increment: 1 μL
    •SPIP-1000: Volume Range: 100-1000 μL, Increment: 5 μL
    •SPIP-5000: Volume Range: 1000-5000 μL, Increment: 50 μL
    •SPIP-10000: Volume Range: 1-10 mL, Increment: 100 μL

  • Memmert ICH260C Climate Chamber [Resale]

    *Additional charge for installation
    *One Science does not handle the warranty for resale items


    Setting temperature range: -10 to +60 °C
    Working temperature range: from -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over)
    Working temperature range: from +10°C up to +60°C with humidity and/or light
    Setting accuracy temperature: 0.1 °C
    Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
    Works calibration certificate: standard values +10 °C and +37 °C, 60 % rh at +30 °C
    Door: inner glass doors
    Door: fully insulated stainless steel doors with 2-point locking (compression door lock)
    Entry port: Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back
    Humidity: humidity supply with distilled water from external tank by self-priming pump
    Humidification: humidification by hot steam generator
    Humidity: active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity – resolution of display 0.1 %, setting accuracy 0.5 %
    Fan: forced air circulation
    External Dimensions: w(D) x h(E) x d(F): 824 x 1552 x 685 mm (d +56mm door handle)
    Internal Dimensions: w(A) x h(B) x d(C): 640 x 800 x 500 mm (d less 33 mm for fan)
    Volume: 256 l
    Max. number of internals: 9
    Max. loading of chamber: 200 kg
    Max. loading per internal: 20 kg