AU680 Clinical Chemistry Analyzer [Resale]
*Additional charge for installation
*One Science does not handle the warranty for resale items
The AU680 clinical chemistry analyzer gives mid- to high-volume laboratories the flexibility to improve efficiencies and economics their way. Operate the AU680 as a standalone system or connect it to laboratory automation and IT solutions. With throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the AU680 clinical chemistry analyzer delivers field-proven reliability and efficiency to laboratories around the world.
System includes:
- Analyzer
- Sampler
- Computer rack
-
8-channel Pipette
*Buy 1 Free 1 Promotion, while stock lasts
A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.
VOLUMES AVAILABLE:
•SPIP-B10: Volume Range: 1-10 μL, Increment: 0.1 μL
•SPIP-B300: Volume Range: 50-300 μL, Increment: 1 μL
•SPIP-B1000: Volume Range: 100-1000 μL, Increment: 5 μL -
Single-channel Pipette
*Buy 1 Free 1 Promotion, while stock lasts
A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.
VOLUMES AVAILABLE:
•SPIP-2.5: Volume Range: 0.1-2.5 μL, Increment: 0.05 μL
•SPIP-10: Volume Range: 1-10 μL, Increment: 0.1 μL
•SPIP-20: Volume Range: 2-20 μL, Increment: 0.1 μL
•SPIP-100: Volume Range: 10-100 μL, Increment: 1 μL
•SPIP-200: Volume Range: 20-200 μL, Increment: 1 μL
•SPIP-1000: Volume Range: 100-1000 μL, Increment: 5 μL
•SPIP-5000: Volume Range: 1000-5000 μL, Increment: 50 μL
•SPIP-10000: Volume Range: 1-10 mL, Increment: 100 μL -
PB-30 pH Meter
Measuring range of pH: -1.99 to 19.99
pH readability: 0.01
pH precision: ±0.005
Measuring range of mV (mV): -1999.9 to 1999.9
mV readability (mV): 0.1
mV precision (mV): ±0.3 mV (0.05%, if +400 mV)
Temperature range (°C): -5.0 to 105.0
Readability (°C): 0.1
Precision (°C): ±0.2
Calibration point: Max. 3 buffers
Automatic identification of buffers:
16 buffers
2, 4, 7, 10, 12
1, 3, 6, 8, 10, 13
1.68, 4.01, 6.86, 9.18, 12.46
Electrode calibration slope range: 90% – 105%
Temperature compensation: Automatic (ATC), manual (MTC)
Optional measurement units: pH, mV and RmV (relative mV value)
OPTIONAL ACCESSORIES:
-
PY-T02 Temperature Sensor
Temperature Sensor; Stainless Steel Body
-
-
PB-10 Standard pH Meter
Measuring range of pH: 0 to 14
pH readability: 0.01
pH precision: ±0.01
Measuring range of mV (mV): -1500.0~ to 1500.0
mV readability (mV): 0.1
mV precision (mV): ±0.4
Temperature range (°C): -5.0 to 105.0
Readability (°C): 0.1
Precision (°C): ±0.2
Calibration point: Max. 3 buffers
Automatic identification of buffers:
16 buffers
2, 4, 7, 10, 12
1, 3, 6, 8, 10, 13
1.68, 4.01, 6.86, 9.18, 12.46
Automatic temperature compensation (ATC): Yes
Display of electrode slope: Yes
Interface: BNC
Display screen: LCD
OPTIONAL ACCESSORIES: