LABNORI 30 Minutes Gas Cylinder Cabinet for 4 cylinders
EN14470-2 Compressed gas cylinder cabinets for the storage of pressurised gas cylinders in working areas. The gas cylinder cabinets of the G-LINE enable the safe storage and removal of gas cylinders in accordancewith regulations in workrooms, The gas cylinder cabinets offer maximum protection and convince with a fire resistance of up to 30 minutes.
1. Even ventilation and extraction of the entire cabinet interior
2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system
3. The potential formation of explosive atmospheres or harmful vapours is safely prevented
4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
5. Includes mounting rails, cylinder retainers with matching tension belts and a rolling ramp
6. The integrated, manually operated rolling ramp facilitates the storage and removal of compressed gas cylinders
7. With the comfort interior, the rolling ramp is conveniently operated by a lever.
8. Large area for flexible lead-through possibilities on the top of the cabinet, no additional insulation of piping necessary -
LABNORI 30 Minutes Gas Cylinder Cabinet for 3 cylinders
EN14470-2 Compressed gas cylinder cabinets for the storage of pressurised gas cylinders in working areas. The gas cylinder cabinets of the G-LINE enable the safe storage and removal of gas cylinders in accordancewith regulations in workrooms, The gas cylinder cabinets offer maximum protection and convince with a fire resistance of up to 30 minutes.
1. Even ventilation and extraction of the entire cabinet interior
2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system
3. The potential formation of explosive atmospheres or harmful vapours is safely prevented
4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
5. Includes mounting rails, cylinder retainers with matching tension belts and a rolling ramp
6. The integrated, manually operated rolling ramp facilitates the storage and removal of compressed gas cylinders
7. With the comfort interior, the rolling ramp is conveniently operated by a lever.
8. Large area for flexible lead-through possibilities on the top of the cabinet, no additional insulation of piping necessary -
LABNORI 30 Minutes Gas Cylinder Cabinet for 2 cylinders
EN14470-2 Compressed gas cylinder cabinets for the storage of pressurised gas cylinders in working areas. The gas cylinder cabinets of the G-LINE enable the safe storage and removal of gas cylinders in accordancewith regulations in workrooms, The gas cylinder cabinets offer maximum protection and convince with a fire resistance of up to 30 minutes.
1. Even ventilation and extraction of the entire cabinet interior
2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system
3. The potential formation of explosive atmospheres or harmful vapours is safely prevented
4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
5. Includes mounting rails, cylinder retainers with matching tension belts and a rolling ramp
6. The integrated, manually operated rolling ramp facilitates the storage and removal of compressed gas cylinders
7. With the comfort interior, the rolling ramp is conveniently operated by a lever.
8. Large area for flexible lead-through possibilities on the top of the cabinet, no additional insulation of piping necessary -
LABNORI 30 Minutes Lithium Battery Storage Cabinet
EN14470-1 flammable cabinet as a robust industrial talent for the safe and compliant storage of flammable hazardous substances. Many different models and equipment variants are available to you for the various areas of application with 90-minute or 30-minute fire resistance. Extreme fire resistance for high-risk environments such as high occupancy sites, high-value/high asset settings, or remote areas that lack fire-fighting services
1. Extremely robust design with scratch-proof surface, triple hinged door for extreme strain
2. Doors stay in place at any opening angle for a more convenient handling of containers
3. Intumescent strips expand to seal gaps in case of fire
4. Hybrid-close door—manual close doors stop in any position, but self-close at 122 F (50 C) under fire conditions
5. Two top vents with butterfly valve close automatically at 158 F (70 ℃) in a fire
6. Integrated air ducts ready for connection (DN 75) to a technical exhaust system can be used for the extraction of hazardous substances vapours, close automatically at 158 F (70 ℃) in a fire
7. Removable sump with perforated insert captures spills—keeps containers elevated to stay dry
8. Integrated transport base for simple inhouse transport, cabinet can be transported upright through doors -
Type 30 Minutes Safety Storage Cabinets
EN14470-1 flammable cabinet as a robust industrial talent for the safe and compliant storage of flammable hazardous substances. Many different models and equipment variants are available to you for the various areas of application with 90-minute or 30-minute fire resistance. Extreme fire resistance for high-risk environments such as high occupancy sites, high-value/high asset settings, or remote areas that lack fire-fighting services
1. Extremely robust design with scratch-proof surface, triple hinged door for extreme strain
2. Doors stay in place at any opening angle for a more convenient handling of containers
3. Intumescent strips expand to seal gaps in case of fire
4. Hybrid-close door—manual close doors stop in any position, but self-close at 122 F (50 C) under fire conditions
5. Two top vents with butterfly valve close automatically at 158 F (70 ℃) in a fire
6. Integrated air ducts ready for connection (DN 75) to a technical exhaust system can be used for the extraction of hazardous substances vapours, close automatically at 158 F (70 ℃) in a fire
7. Removable sump with perforated insert captures spills—keeps containers elevated to stay dry
8. Integrated transport base for simple inhouse transport, cabinet can be transported upright through doors -
Type 90 Minutes Safety Storage Cabinets FLAB9120
1. Doors lockable with cylinder lock
2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system can be used for the extraction of hazardous substances vapours
3. Extremely robust design with scratch-proof surface
4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
5. Doors stay in place at any opening angle for a more convenient handling of containers
6. Integrated transport base for simple inhouse transport, cabinet can be transported upright through doors -
Safety Showers and Eyewash SS3011
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Emergency Showers and Eyewash with Epoxy SS3001Y
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Safety Showers and Eyewash SS3001
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration.