TT200FT Tecan Tips
Tecan Evo Compatible 200ul, Black Conductive, Filtered, Sterile
Rack Box Packaging
96PC/RACK, 16RACK/CTN
Sterility Expiration: 31 Oct 2024 -
Fully Autoclavable Mechanical Pipette
Single-channel Adjustable Volume
• Ergonomic Design
• Ultralight Weight
• Calibrated with accordance to ISO8655-2
Volume:
• 7030511001 Hipette: 0.1-2.5ul
• 7030511004 Hipette: 0.5-10ul
• 7030511005 Hipette: 2-20ul
• 7030511006 Hipette: 5-50ul
• 7030511008 Hipette: 10-100ul
• 7030511009 Hipette: 20-200ul
• 7030511040 Hipette: 30-300ul
• 7030511014 Hipette: 100-1000ul
• 7030511043 Hipette: 1000-5000ul
• 7030511033 Hipette: 2-10ml -
Rainin LTS Compatible Reload Racked Tips
Specification:
• Rainin LTS Compatible
• Low retention and Normal Retention available
• RNAse/DNase-free
• Non-Sterile
• Reload Packing
Sizes:
• LTS-20-E: 20μL Non-Filtered Tip (Reloads), Non-sterile, 96PC/RACK, 10 RACK/BOX, 10BOX/CTN
• LTS-20-EL: 20μL Non-Filtered Tip (Reloads), Non-sterile, Low Retentions, 96PC/RACK, 10 RACK/BOX, 10BOX/CTN
• LTS-200-E: 200μL Non-Filtered Tip (Reloads), Non-sterile, 96PC/RACK, 10 RACK/BOX, 10BOX/CTN
• LTS-200-EL: 200μL Non-Filtered Tip (Reloads), Non-sterile, Low Retentions, 96PC/RACK, 10 RACK/BOX, 10BOX/CTN
• LTS-300-E: 300μL Non-Filtered Tip (Reloads), Non-sterile, 96PC/RACK, 10 RACK/BOX, 10BOX/CTN
• LTS-300-EL: 300μL Non-Filtered Tip (Reloads), Non-sterile, Low Retentions, 96PC/RACK, 8 RACK/BOX, 10BOX/CTN
• LTS-1000-E: 1000μL Non-Filtered Tip (Reloads), Non-sterile, 96PC/RACK, 5 RACK/BOX, 10BOX/CTN
• LTS-1000-EL: 1000μL Non-Filtered Tip (Reloads), Non-sterile, Low Retentions, 96PC/RACK, 5 RACK/BOX, 10BOX/CTN -
Rainin LTS Compatible Filter Tips
Specification:
• Rainin LTS Compatible
• Low retention and Normal Retention available
• RNAse/DNase-free
• Sterile
• Packing: 96PC/RACK, 10RACK/BOX, 5BOX/CTN
Sizes:
• LTSF-20-RS: 20μL Filtered Tip, Sterile
• LTSF-20-RSL: 20μL Filtered Tip, Sterile, Low Retention
• LTSF-200-RS: 200μL Filtered Tip, Sterile
• LTSF-200-RSL: 200μL Filtered Tip, Sterile, Low Retention
• LTSF-300-RS: 300μL Filtered Tip, Sterile
• LTSF-300-RSL: 300μL Filtered Tip, Sterile, Low Retention
• LTSF-1000-RS: 1000μL Filtered Tip, Sterile
• LTSF-1000-RSL: 1000μL Filtered Tip, Sterile, Low Retention -
Filtered Pipette Tips
Specification:
• Low retention with graduations
• Sterile
• Universal fitting
• Packing: 96PC/RACK, 10RACK/BOX, 5BOX/CTN
Sizes:
• MF-TR-9610-33: Short 10uL (length: 33mm)
• MF-TR-9610-46: Long 10uL (length: 46mm)
• MF-TR-9620: 20uL (length: 60mm)
• MF-TR-96100: 100uL (length: 60mm)
• MF-TR-96200: 200uL (length: 60mm)
• MF-TR-96300: 300uL (length: 60mm)
• MF-TR-961250: 1250uL (length: 102mm) -
Reload Packed Pipette Tips (Non-filtered Tip)
Specification:
• Reload Stacked Packaging (non-filtered tip), pipette tip box is not included
• Universal fitting (Gilson, Eppendorf, Finnpipette)
• Can be used to reload TF range pipette tip boxes
Sizes:
• T-10-E: 10uL (length: 32mm), Transparent, 96PC/RACK, 10 RACK/BOX, 10 BOX/CTN
• T-200Y-E: 200uL (length: 50.5mm), Yellow, 96PC/RACK, 10 RACK/BOX, 10 BOX/CTN
• T-300-E: 300uL (length: 59.5mm), Transparent, 96PC/RACK, 10 RACK/BOX, 10 BOX/CTN
• T-1000B-E : 1000uL (length: 87.7mm), Transparent, 96PC/RACK, 5 RACK/BOX, 10 BOX/CTN
• T-1250-E: 1250uL (length: 101.9mm), Transparent, 96PC/RACK, 5 RACK/BOX, 10 BOX/CTN -
Filtered Pipette Tips (Non-filtered Tips Reload Pack available)
Specification:
• Filtered Tip
• Low retention with graduations available
• Sterile
• Universal fitting (Gilson, Eppendorf, Finnpipette)
• Packing: 96PC/RACK, 10 RACK/BOX, 5 BOX/CTN
• Pipette tip boxes can be reused by reloading with Non-filtered Tips Reload Pack
Sizes:
• TF-10-RSL: Short 10uL (length: 32mm), Transparent
• TF-11-RSL: Long 10uL (length: 45.9mm), Transparent
• TF-20Y-RSL: 20uL (length: 50.5mm), Yellow
• TF-100-RSL: 100uL (length: 59.5mm), Transparent
• TF-200-RSL: 200uL (length: 59.5mm), Yellow
• TF-300-RSL: 300uL (length: 59.5mm), Transparent
• TF-1000B-RSL: 1000uL (length: 87.7mm), Transparent
• TF-1250-RSL: 1250uL (length: 101.9mm), Transparent -
BSC-1804IIA2 Biological Safety Cabinet, 6 feet, Class II Type A2
Includes:
•NSF 49 Certification for the 1st year
•UV lamp (1 pc)
•Sockets (2 pcs)
•Valves (2 pcs)
•Adjustable stand
Friendly Control Panel
•Color LED screen, show the air velocity, time, fan station, HEPA filter life and alarm in real time
Safe and Reliable, Energy-Efficient
•DC fan and LED light make the operation power consumption save 30%.
•Intelligent auto-supply system of imported blower ensures the change of air volume less than 10% when the resistance of filter increases 50% and enhance safety.
•The alarm system for safe operation height is interlocked with light. At the same time light is interlocked with sterilizing.
•Leak detection in cabinet, no leakage at 500Pa.
•UV light with set timer, safer and high efficiency.
Humanized design
•10°sloped front make it comfortable to operator.
•Negative pressure and double layers chamber around ensure non-leakage, non-pollution.
•Demountable circular-arc armrest can alleviate working tiredness and make it easy to transport.
•Front window adopts hanging lifting system (Imported from Japan) and more than 5mm thickness security glass with arbitrary positioning, high stability and convenient to sterilization when it closed.
•Front window can be cleaned all-over, solving the problem which front window can’t be cleaned inside
•Moveable working table with handle and support make it easier to clean collecting tank.
•There are two anti-splash spare sockets and four service port in the cabinet.
•Movable stainless steel worktable 4 liter capacity stainless steel collecting tank with below down valve, easy to collect water, cleaning and disinfection.
•Non-obstructive air return mode in the front suction channel .
•The adjustable leveling foot is without exposure thread.
ULPA filters
•USA HV ULPA Filter Medium, provide 99.9995% typical efficiency for particle size over 0.12 microns, and the materials is glass fiber.
• minimum ISO 4 air quality in the work area
•Unique Technology of non leakage
•Every ULPA filters will be tested to ensure non leakage.
ECO mode and power off memory function
•You need not to turn off BSC when stop experiment. You can close front window and BSC will turn to ECO mode to ensure cleanliness in working area. If opening front window, BSC will turn to normal mode immediately.
•If losing power unexpected, BSC will return to the station which before losing power when regain power. This will ensure the safety of operator. -
BSC-1302IIA2 Biological Safety Cabinet 4 feet, Class II Type A2
Includes:
•NSF 49 Certification for the 1st year
•Sockets (2 pcs)
•Valves (2 pcs)
•Detachable stand with adjustable height
Friendly Control Panel
•LED screen, show the air velocity, time, fan station, alarm in real time.
Safe and Reliable, Energy-Efficient
•DC fan and LED light make the operation power consumption save 30%.
•Intelligent auto-supply system of imported blower ensures the change of air volume less than 10% when the resistance of filter increases 50% and enhance safety.
•The alarm system for safe operation height is interlocked with light. At the same time light is interlocked with sterilizing.
•Leak detection in cabinet, no leakage at 500Pa.
•UV light with set timer, safer and high efficiency.
Humanized design
•10°sloped front make it comfortable to operator.
•Negative pressure and double layers chamber around ensure non-leakage, non-pollution.
Demountable circular-arc armrest can alleviate working tiredness and make it easy to transport.
•Front window adopts hanging lifting system (Imported from Japan) and more than 5mm thickness security glass with arbitrary positioning, high stability and convenient to sterilization when it closed.
•Movable stainless steel worktable 4 liter capacity stainless steel collecting tank with below down valve, easy to collect water, cleaning and disinfection.
•Non-obstructive air return mode in the front suction channel.
•The adjustable leveling foot is without exposure thread.
HEPA filters
•USA HV HEPA Filter Medium, provide 99.995% typical efficiency for particle size over 0.3 microns, and the materials is glass fiber.
•A minimum ISO 5 air quality in the work area
•Unique Technology of non leakage.
•Every HEPA filters will be tested to ensure non leakage.