• 8-channel Pipette

    *Buy 1 Free 1 Promotion, while stock lasts


    A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.


    VOLUMES AVAILABLE:
    •SPIP-B10: Volume Range: 1-10 μL, Increment: 0.1 μL
    •SPIP-B300: Volume Range: 50-300 μL, Increment: 1 μL
    •SPIP-B1000: Volume Range: 100-1000 μL, Increment: 5 μL

  • Single-channel Pipette

    *Buy 1 Free 1 Promotion, while stock lasts


    A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.


    VOLUMES AVAILABLE:
    •SPIP-2.5: Volume Range: 0.1-2.5 μL, Increment: 0.05 μL
    •SPIP-10: Volume Range: 1-10 μL, Increment: 0.1 μL
    •SPIP-20: Volume Range: 2-20 μL, Increment: 0.1 μL
    •SPIP-100: Volume Range: 10-100 μL, Increment: 1 μL
    •SPIP-200: Volume Range: 20-200 μL, Increment: 1 μL
    •SPIP-1000: Volume Range: 100-1000 μL, Increment: 5 μL
    •SPIP-5000: Volume Range: 1000-5000 μL, Increment: 50 μL
    •SPIP-10000: Volume Range: 1-10 mL, Increment: 100 μL

  • PB-30 pH Meter

    Measuring range of pH: -1.99 to 19.99

    pH readability: 0.01

    pH precision: ±0.005

    Measuring range of mV (mV): -1999.9 to 1999.9

    mV readability (mV): 0.1

    mV precision (mV): ±0.3 mV (0.05%, if +400 mV)

    Temperature range (°C): -5.0 to 105.0

    Readability (°C): 0.1

    Precision (°C): ±0.2

    Calibration point: Max. 3 buffers

    Automatic identification of buffers:

    16 buffers

    2, 4, 7, 10, 12

    1, 3, 6, 8, 10, 13

    1.68, 4.01, 6.86, 9.18, 12.46

    Electrode calibration slope range: 90% – 105%

    Temperature compensation: Automatic (ATC), manual (MTC)

    Optional measurement units: pH, mV and RmV (relative mV value)

     

    OPTIONAL ACCESSORIES:

  • PB-10 Standard pH Meter

    Measuring range of pH: 0 to 14

    pH readability: 0.01

    pH precision: ±0.01

    Measuring range of mV (mV): -1500.0~ to 1500.0

    mV readability (mV): 0.1

    mV precision (mV): ±0.4

    Temperature range (°C): -5.0 to 105.0

    Readability (°C): 0.1

    Precision (°C): ±0.2

    Calibration point: Max. 3 buffers

    Automatic identification of buffers:

    16 buffers

    2, 4, 7, 10, 12

    1, 3, 6,  8,  10, 13

    1.68, 4.01, 6.86, 9.18, 12.46

    Automatic temperature compensation (ATC): Yes

    Display of electrode slope: Yes

    Interface: BNC

    Display screen: LCD


    OPTIONAL ACCESSORIES:

Need Help?