Memmert ICH260C Climate Chamber [Resale]
*Additional charge for installation
*One Science does not handle the warranty for resale items
Setting temperature range: -10 to +60 °C
Working temperature range: from -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over)
Working temperature range: from +10°C up to +60°C with humidity and/or light
Setting accuracy temperature: 0.1 °C
Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Works calibration certificate: standard values +10 °C and +37 °C, 60 % rh at +30 °C
Door: inner glass doors
Door: fully insulated stainless steel doors with 2-point locking (compression door lock)
Entry port: Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back
Humidity: humidity supply with distilled water from external tank by self-priming pump
Humidification: humidification by hot steam generator
Humidity: active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity – resolution of display 0.1 %, setting accuracy 0.5 %
Fan: forced air circulation
External Dimensions: w(D) x h(E) x d(F): 824 x 1552 x 685 mm (d +56mm door handle)
Internal Dimensions: w(A) x h(B) x d(C): 640 x 800 x 500 mm (d less 33 mm for fan)
Volume: 256 l
Max. number of internals: 9
Max. loading of chamber: 200 kg
Max. loading per internal: 20 kg -
PB-30 pH Meter
Measuring range of pH: -1.99 to 19.99
pH readability: 0.01
pH precision: ±0.005
Measuring range of mV (mV): -1999.9 to 1999.9
mV readability (mV): 0.1
mV precision (mV): ±0.3 mV (0.05%, if +400 mV)
Temperature range (°C): -5.0 to 105.0
Readability (°C): 0.1
Precision (°C): ±0.2
Calibration point: Max. 3 buffers
Automatic identification of buffers:
16 buffers
2, 4, 7, 10, 12
1, 3, 6, 8, 10, 13
1.68, 4.01, 6.86, 9.18, 12.46
Electrode calibration slope range: 90% – 105%
Temperature compensation: Automatic (ATC), manual (MTC)
Optional measurement units: pH, mV and RmV (relative mV value)
OPTIONAL ACCESSORIES:
-
PB-10 Standard pH Meter
Measuring range of pH: 0 to 14
pH readability: 0.01
pH precision: ±0.01
Measuring range of mV (mV): -1500.0~ to 1500.0
mV readability (mV): 0.1
mV precision (mV): ±0.4
Temperature range (°C): -5.0 to 105.0
Readability (°C): 0.1
Precision (°C): ±0.2
Calibration point: Max. 3 buffers
Automatic identification of buffers:
16 buffers
2, 4, 7, 10, 12
1, 3, 6, 8, 10, 13
1.68, 4.01, 6.86, 9.18, 12.46
Automatic temperature compensation (ATC): Yes
Display of electrode slope: Yes
Interface: BNC
Display screen: LCD
OPTIONAL ACCESSORIES: