Type 90 Minutes Safety Storage Cabinets FLAB9120
1. Doors lockable with cylinder lock
2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system can be used for the extraction of hazardous substances vapours
3. Extremely robust design with scratch-proof surface
4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
5. Doors stay in place at any opening angle for a more convenient handling of containers
6. Integrated transport base for simple inhouse transport, cabinet can be transported upright through doors -
Safety Showers and Eyewash SS3011
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Emergency Showers and Eyewash with Epoxy SS3001Y
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Safety Showers and Eyewash SS3001
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Atomic Absorption Spectrophotometer
Flame AAS
Single beam
Holographic diffraction grating with 1800 lines/mm
Slit: 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Accuracy: ±0.3 nm
Automated 4-lamp turret
Photomultiplier tube detector
Working mode: T, A, C
Deuterium (D2) Background Correction -
Balance TA2204
Display: 4.3 inch touch screen
Capacity & Readability: 0.1mg/220g
Calibration: Internal
Weighing Units: g, ct, oz, lb, ozt, N
Pan Size: 85mm
Stabilization Time: ≤4 seconds
Communication: USB
Assembled Dimensions & N.W.: 210*360*330mm/6KG -
Balance TA205C
Display: 4.3 inch touch screen
Capacity & Readability: 0.01mg/20g
Calibration: Internal
Weighing Units: g, ct, oz, lb, ozt, N
Pan Size: 85mm
Stabilization Time: ≤4 seconds
Communication: USB
Assembled Dimensions & N.W.: 210*360*330mm/6KG -
Omron button pH meter S-610L
Range: (-2.00-18.00)pH
Accuracy: ±0.02pH
mV: -1999.9mV-0-1999.9mV
Temperature: 0-100℃
Accuracy: ±0.01pH(S-610H) -
Touchscreen pH meter T-710L
Range: (-2.00-19.99)pH
Accuracy: ±0.02pH
mV: -1999.9mV-0-1999.9mV
Temperature: -10-110℃
Accuracy: ±0.01pH(T-710H) -
Spectrophotometer E-2100V
Display: 7-inch capacitive touch screen
Optical: UV Visible single beam
Spectral bandwidth: 4nm
Wavelength range: 320-1100nm
Wavelength accuracy: ±1nm
Photometric range: 0-200%T, -0.3-3A
Stray light: ≤0.1%T@220nm, 360nm
Working mode: T, A, C, E
Light source: Tungsten Halogen -
Spectrophotometer C-7200
Display: 7-inch color screen with silicone button
Optical: UV/Vis double beam
Spectral bandwidth: 2nm
Wavelength accuracy: ±0.3nm
Photometric range: 0-200%T, -0.3~3A, 0-9999C
Stray light: ≤0.03%T@220nm, 360nm
Baseline flatness: ±0.003A
Working mode: T, A, C, E
Light source: Tungsten Halogen/Deuterium lamps