Automatic Electronic Pipette
Major Features of Automatic pipettes:
•No manual, no pipetting mode, more fast and convenient.
•One pipette can finish your experiment from beginning to end.
•A operator thinks what a machine can do.
MODEL AVAILABLE:
AE-EP0010 0.2-10ul
AE-EP0020 0.5-20ul
AE-EP0100 2-100ul
AE-EP0200 5-200ul
AE-EP0300 10-300ul
AE-EP0500 10-500ul
AE-EP1000 50-1000ul
AE-EP5000 0.1-5ml
AE-EP10000 1-10ml
Single Channel Pipette for Polymerase chain reaction (PCR)
(Note: This Series pipette is more suitable for Polymerase chain reaction and molecular experiment):
AE-EP10P: 0.2-10ul
AE-EP200P: 5-200ul
AE-EP1000P: 50-1000ul -
8 & 12 Channel Electronic Pipette
Major Features of Automatic pipettes:
•No manual, no pipetting mode, more fast and convenient.
•One pipette can finish your experiment from beginning to end.
•A operator thinks what a machine can do.
MODEL AVAILABLE:
8 channel:
AE-EP8011 0.2-10μl
AE-EP8021 5-100μl
AE-EP8031 10-300μl
12 channel:
AE-TP1201 0.2-10μl
AE-TP1202 5-100μl
AE-TP1203 10-300μl -
SMART MECHANICAL ULTRASONIC CLEANER
TIME
•1~60minutes or Always on
•Encoded Control of high-precision
HEAT
•0~80°C Temperature Range
•Encoded Control of high-precision
MODEL AVAILABLE:
AE-10: 2L
AE-20: 3.2L
AE-30: 6.5L
AE-40: 10L
AE-60: 15L
AE-80: 22L
AE-100: 30L -
DMP-800 Melting Point Device
Melting point device is widely using in chemical industry and medicine. It is a necessary instrument for the production of food, drugs, spices, dyes and other organic crystal substances.
Model DMP-800
Temperature Range Room Temperature to 400℃
Cooling Function Built-in cooling fan
Resolution 0.1℃
Temperature Increase Speed 0.1℃-10℃ (100temperature point infinitely adjustable) -
PI-100 Portable Incubator
Model PI-100
Temp. Range 5°C to 60°C
Temp. Accuracy ±0.2°C
Temp. Uniformity ± 0.5°C
Temp. Stability ±0.2°C
Temp. Increment 0.1°C
Max Steps of Temp. 5 -
Memmert ICH260C Climate Chamber [Resale]
*Additional charge for installation
*One Science does not handle the warranty for resale items
Setting temperature range: -10 to +60 °C
Working temperature range: from -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over)
Working temperature range: from +10°C up to +60°C with humidity and/or light
Setting accuracy temperature: 0.1 °C
Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Works calibration certificate: standard values +10 °C and +37 °C, 60 % rh at +30 °C
Door: inner glass doors
Door: fully insulated stainless steel doors with 2-point locking (compression door lock)
Entry port: Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by a silicone stopper, standard position at the back
Humidity: humidity supply with distilled water from external tank by self-priming pump
Humidification: humidification by hot steam generator
Humidity: active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity – resolution of display 0.1 %, setting accuracy 0.5 %
Fan: forced air circulation
External Dimensions: w(D) x h(E) x d(F): 824 x 1552 x 685 mm (d +56mm door handle)
Internal Dimensions: w(A) x h(B) x d(C): 640 x 800 x 500 mm (d less 33 mm for fan)
Volume: 256 l
Max. number of internals: 9
Max. loading of chamber: 200 kg
Max. loading per internal: 20 kg