Type 90 Minutes Safety Storage Cabinets FLAB9120
1. Doors lockable with cylinder lock
2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system can be used for the extraction of hazardous substances vapours
3. Extremely robust design with scratch-proof surface
4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
5. Doors stay in place at any opening angle for a more convenient handling of containers
6. Integrated transport base for simple inhouse transport, cabinet can be transported upright through doors -
Safety Showers and Eyewash SS3011
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Emergency Showers and Eyewash with Epoxy SS3001Y
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
Safety Showers and Eyewash SS3001
In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.
However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration. -
DB Series Dry Bath
R.T.+5℃~100℃/ -15℃~100℃, price excluding block
Fast efficient sample concentration suitable for a variety of tubes not including centrifuges tubes but also capillary tubes. We also can design the model you wanted for you,
MODEL:
• DB100: Temperature Range: Room Temp +5℃~100℃
• DB100-C: Temperature Range: Room Temp -15℃~100℃
OPTIONAL ACCESSORIES:
• DB1 / Centrifuge tube, 96*0.2ml
• DB2 / Centrifuge tube, 48*0.5ml
• DB3 / Centrifuge tube, 35*1.5ml
• DB4 / Centrifuge tube, 35*2ml
• DB5 / Centrifuge tube, 24*5ml
• DB6 / Centrifuge tube 15ml *5/12
• DB7 / Centrifuge tube 50ml*6
• DB8 / Flat Bottom Plate( ELISA Plate/Culture Plate)
• DB9 / Cuvettes Dedicated Module
• DB10 / OEM Model -
VM500 Series Vortex Mixer
price excluding all block
Our Vortex Mixer with Multiple Model can fit for different experiment request, the biggest volume for the tubes can be 50ml, and also fit for capillary tubes with diamater 12mm. Different models change easily and fit for lots of different kinds of tubes.
MODEL:
• VM500S: 200-3000rpm
• VM500pro: 100-3000rpm
OPTIONAL ACCESSORIES:
• VM501 / Centrifuge tube/test tube
• VM502/ Flask or multiple tubes
• VM503/ Capillary tubes,φ12mm*21
• VM505/ Centrifuge tube, 50ml*4 / Centrifuge tube 5ml/15ml*5
• VM506/ Centrifuge tube, 0.2ml *96 / 96 well plate
• VM507/ Centrifuge tube 0.5ml *20/ Centrifuge tube 1.5ml/2.0ml *30
• VM508/ Cell culture plate -
VP-10L/15L/15S/30L Vacuum Pump
Our Vacuume Pumps are portable and easy to operate. This system combined by a vacuum pump and a collection bottle, which is widely used for sample aspiration/collection in biochemistry and medical engineering experiments like centrifugal liquid supernatant or sediment, Elisa plate washing and biochemical analyzer liquid.
MODEL:
• VP-10L: 10L/min, Vaccum degree: 0.075mpa, Negative Pressure
• VP-15L: 15L/min, Vaccum degree: 0.08mpa, Negative Pressure
• VP-15S: 0-15L/min, Vaccum degree: 0.08mpa, Negative Pressure
• VP-30L: 30L/min, Vaccum degree: 0.085mpa, Positive and Negative Pressure -
MC5pro/7pro/10pro/12pro/13pro/15pro Mini Centrifuge
Our Mini Centrifuge with small size but large capacity, eapecially our rotor put centrifuge tubes and blood tube into 1 rotor so that make experiment more convenient. The larggest speedn can over 10000rpm which can instantaneous centrifugation.
Rotor for MC5pro/ MC7pro/ MC10pro/ MC12pro:
• centrifuge tubes:0.2/0.5/1.5/2ml*12
• 0.2ml*8*4
• Micro Blood Tube:0.1/0.5ml*12
Rotor for MC13pro/ MC15pro:
• centrifuge tubes:0.2/0.5/1.5/2ml*12
• Micro Blood Tube:0.1/0.5ml*12
MODEL:
• MC5pro: 1000-5000rpm/ RCF: 1680*g
• MC7pro: 1000-7000rpm/ RCF: 3286*g
• MC10pro: 1000-10000rpm/ RCF: 6708*g
• MC12pro: 1000-12000rpm/ RCF: 9660*g
• MC13pro: 1000-13000rpm/ RCF: 11337*g
• MC15pro: 1000-15000rpm/ RCF: 14104*g -
RM6pro/RM8pro Roller Mixer
Our Roller Mixer have six and eight rollers for your choosing, with large length 280mm, fit for different tubes with different diameter. Especially fit for Blood Collection Work.
MODEL:
• RM6pro: 6 rollers
• RM8pro: 8 rollers -
VM210/300/300S Mini Size Vortex Mixer
Our Mini Size Vortex Mixers are portable and smart, small size but with higher speed, use for liquid mixing.
MODEL:
• VM210: 2100rpm
• VM300: 3000rpm
• VM300S: 0-3000rpm -
MHS 4pro/6pro Multiple Magnetic Stirrer with heating
Our Multiple Magnetic Stirrer with heating can work synchronizable and asynchronous, you can choose the positions, speed, time and temperature by yourselves then have a mixing, the stirrer bars will copy with the capacity.
MODEL:
• MHS 4pro: 50-1100rpm/500ml*4
• MHS 6pro: 50-1100rpm/ 500ml*6 -
MMS 4pro/6pro Multiple Magnetic Stirrer
Our Multiple Magnetic Stirrer can work synchronizable and asynchronous, you can choose the positions, speed and time by yourselves then have a mixing, the stirrer bars will copy with the capacity.
MODEL:
• MMS 4pro: 50-1500 rpm / 500ml*4
• MMS 6pro: 50-1300 rpm /500ml*6 -
MS10L/15L/30L/50L/100L Large Capacity Magnetic Stirrer
Our Large Capacity Magnetic Stirrers with LCD display,timing. Not only use botton but also knob control to finish easy operation.
MODEL:
• MS10: 50-1500rpm /10L (Chamber size: 220mm)
• MS15: 50-1300rpm /15L (Chamber size: 220mm)
• MS30: 50-1100rpm/30L (Chamber size: 260mm)
• MS50: 50-1100rpm/50L (Chamber size: 330mm)
• MS100: 100-600rpm/100L (Chamber size: 400mm) -
MS3/MS5/MS5S Mini Size Magnetic Stirrer
Our Mini Size Magnetic Stirrers are portable and easy to operate, small size with strong magnetic filed and large mxing ability. We especially choose brushless motor to inrease the continuous serviceability. Fits for laboratory mixing also work for coffee mixing.
MODEL:
• MS3: 200-1800rpm/1L (Size diamater: 125mm)
• MS5: 350-1800rpm/2L (Size diamater: 135mm)
• MS5S: 200-2000rpm/2L (Size diamater: 135mm)