• Type 90 Minutes Safety Storage Cabinets FLAB9120

    1. Doors lockable with cylinder lock
    2. Integrated air ducts ready for connection (DN 75) to a technical exhaust system can be used for the extraction of hazardous substances vapours
    3. Extremely robust design with scratch-proof surface
    4. Door lockable with cylinder lock, the cabinets can be integrated by the customer into an existing locking system
    5. Doors stay in place at any opening angle for a more convenient handling of containers
    6. Integrated transport base for simple inhouse transport, cabinet can be transported upright through doors

  • Safety Showers and Eyewash SS3011

    In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.



    However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration.

  • Emergency Showers and Eyewash with Epoxy SS3001Y

    In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.



    However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration.

  • Safety Showers and Eyewash SS3001

    In general, the ANSI standard provides that emergency equipment be installed within 10 seconds walking time from the location of the hazard. The equipment must be installed on the same level as the hazard (i.e. accessing the equipment should not require going up or down stairs or ramps). The path of travel from the hazard to the equipment should be free of obstructions and as straight as possible. Users of the equipment should not have to walk around machinery or other obstacles to reach the unit.



    However, there are certain circumstances where these guidelines might not be adequate. For example, where workers are handling particularly strong acids, caustics or other materials where the consequences of a spill would be very serious, emergency equipment should be installed immediately adjacent to the hazard. Laboratory environments also require special consideration.

  • Eppendorf Centrifuge 5810 R Bundle [Resale]

    *Additional charge for installation
    *One Science does not handle the warranty for resale items
    *Bundle includes:
    i. Centrifuge 5810 R (keypad, refrigerated), with Rotor A-4-62 incl. adapters for 15/50 mL conical tubes (5811000363) x 1
    Max. capacity of conical tubes per rotor: 36 × 15 mL/16 × 50 mL
    ii. Adapter for 1 bottle 200 – 250 mL flat/ 175 – 225 mL conical, for 250 mL rectangular bucket in Rotor A-4-62 (5810770009) x 2


    The high-speed Centrifuge 5810 R is one of the smallest 3 L benchtop centrifuge currently available. It is the workhorse for medium to high-throughput laboratories and combines versatility and high capacity to allow you to use both tubes and plates.
    •Temperature range from -9 °C to 40 °C
    •FastTemp function for fast pre-cooling
    •Continuous cooling maintains a constant temperature after the run has been completed – your samples stay cool
    •ECO shut-off engages after 8 hours of non-use to reduce energy consumption and to extend compressor life
    •Dynamic compressor control (DCC) technology for optimized cooling performance

  • Eppendorf Research® Plus Pipette

    The Eppendorf Research plus is one of the safest and most ergonomic mechanical pipettes available. Meeting the highest needs of precision and accuracy while providing high flexibility via a large number of variants, the Research plus will become an indispensable companion in your lab. This micropipette is remarkably light, both in terms of weight and pipetting forces, which helps you to avoid hand and arm strain.


    MODEL:

    • 0.1 – 2.5 μL
    • 0.5 – 10 μL
    • 2 – 20 μL
    • 10 – 100 μL
    • 20 – 200 μL
    • 100 – 1000 μL
  • Eppendorf Research® plus, 3-pipettes-pack

    The Eppendorf Research plus is one of the safest and most ergonomic mechanical pipettes available. Meeting the highest needs of precision and accuracy while providing high flexibility via a large number of variants, the Research plus will become an indispensable companion in your lab. This micropipette is remarkably light, both in terms of weight and pipetting forces, which helps you to avoid hand and arm strain.


    OPTIONS:

    • Option 1: 0.5 – 10 μL, 10 – 100 μL, 100 – 1,000 μL
    • Option 2: 2 – 20 μL, 20 – 200 μL, 100 – 1,000 μL